Year : 2018  |  Volume : 4  |  Issue : 2  |  Page : 62-64

Low-temperature plasma radiofrequency ablation in phantom limb pain: A case report


1 Department of General Surgery; Department of Pain Management; Department of Central Laboratory, Xuanwu Hospital of Capital Medical University; Department of Liver Cancer Center, Beijing, China
2 Department of Pain Management, Xuanwu Hospital of Capital Medical University, Beijing, China
3 Department of Pain Management, Xuanwu Hospital of Capital Medical University; Department of Anesthesia, Beijing Renhe Hospital, Beijing, China
4 Department of Nursing management, The 302 Hospital, Beijing, China
5 Department of Liver Cancer Center, The 302 Hospital, Beijing, China
6 Department of Clinical, Nanjing Medical University, Nanjing, China
7 Department of Radiology, Beijing Water Resources Hospital, Beijing, China
8 Department of Anesthesia, Beijing Renhe Hospital, Beijing, China
9 Department of General Surgery, Xuanwu Hospital of Capital Medical University, Beijing, China

Date of Submission10-May-2017
Date of Decision20-Apr-2018
Date of Acceptance09-May-2018
Date of Web Publication29-Jun-2018

Correspondence Address:
Prof. Fei Li
Departments of General Surgery, Xuanwu Hospital of Capital Medical University, Beijing
China
Prof. Jiaxiang Ni
Department of Pain Management, Xuanwu Hospital of Capital Medical University, Beijing
China
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/bc.bc_7_17

Rights and Permissions
  Abstract 

Phantom limb pain (PLP) and phantom limb sensations are common complications postamputation. PLP is defined as persistent painful sensations perceived in the missing portion of the amputated limb. Low-temperature plasma radiofrequency ablation (coblation) technology is a relatively new technology that has shown promise in treating neuropathic pain. This report illustrates the use of coblation technology on cervical nerve roots for PLP. Coblation of the cervical nerve root was performed. Three 17G puncture trocars were placed near the C5–C6, C6–C7, and C7–T1 intervertebral foramen with computed tomography (CT) guidance. Then, a coblation needle attached to low-temperature plasma multifunctional operation system was placed near the C8 nerve root through the puncture trocars. To locate the target nerve, single stimulation (lasting for 5 s, at 1 intensity) in “cut” and “coagulation” model was given to serve as a sensory stimulation test. The stimulation induced radiating pain of the stimulated nerve away from the stimulation site to confirm our target nerve. The needle location was redirected based on the reproduction of the patient's symptoms with minimal intensity. A CT-guided cervical nerve root coblation was performed to obtain longer PLP relief. The patient reported pain relief in PLP after the operation. At 1-, 3-, and 6-month postoperative review, PLP relief was achieved. Overall activity was improved and there was necessarily need for pain medications. However, the doses of medicine significantly decreased. The analgesic effect was stable during the 6-month follow-up period. Our report demonstrates that coblation technology is successful treatment for PLP in this case. It will supply us a novel navigation in PLP treatments. Meanwhile, this finding still needs additional study for confirmation.

Keywords: Amputation, coblation, phantom limb pain


How to cite this article:
Li H, Li Y, Guo Z, Hao L, Li Y, Tang Y, Guo Y, Zhang D, He L, Wang Y, Meng Y, Li F, Ni J. Low-temperature plasma radiofrequency ablation in phantom limb pain: A case report. Brain Circ 2018;4:62-4

How to cite this URL:
Li H, Li Y, Guo Z, Hao L, Li Y, Tang Y, Guo Y, Zhang D, He L, Wang Y, Meng Y, Li F, Ni J. Low-temperature plasma radiofrequency ablation in phantom limb pain: A case report. Brain Circ [serial online] 2018 [cited 2023 Jun 4];4:62-4. Available from: http://www.braincirculation.org/text.asp?2018/4/2/62/235617


  Introduction Top


Amputation is the removal of a body extremity which is generally caused by severe trauma, circulatory disorders, neoplasm, deformities, and infection of the limb. Historically, phantom limb pain (PLP) and phantom limb sensations are common complications postamputation, and the prevalence of PLP has been reported to be as high as 75%–80%.[1],[2] PLP is defined as persistent painful sensations perceived in the missing portion of the amputated limb.[3] Pain mechanisms involved in PLP include formation of neuroma and ectopic discharge. Although the exact etiology and pathophysiology mechanisms of PLP remain unknown, it is often considered as neuropathic pain (NP) because of dysfunctions in the central and peripheral nervous system.[4],[5],[6],[7],[8]

Nowadays, managements and treatments for PLP are often difficult and challenging. In the past decades, medication, as the most common analgesic modality, is conveniently and extensively utilized for pain management.[9] However, many pharmacological interventions for PLP have shown only limited success, and few of them have evidence-based efficacy and safety.[10],[11],[12] Meanwhile, several case reports for the treatment of PLP also present no medical interventions, such as preemptive analgesia, neuromodulation, mirror therapy, graded motor imagery, stump liners, acupuncture, transcranial magnetic stimulation, and cauda equina stimulation.[13],[14],[15],[16],[17],[18] However, it is rare that randomized controlled trial (RCT) is designed. Therefore, it is firstly demonstrated that low-temperature plasma radiofrequency ablation (coblation) in phantom upper limb pain was reported as a case report.


  Case Report Top


A 71-year-old female patient underwent right arm amputation surgery 40 years ago. After operation, the patient soonly recovery without infection. However, she was experienced with PLP sooner. Her past medical history was significant for diabetes and hypertension. Recently, she complained of severe right PLP for 2 years. Pain in the pain clinic was described as a continuous stabbing, burning pain with the initial visual analog scale (VAS) intensity rating of 8/10 (0 is no pain and 10 is the most severe pain imaginable). The principal site of her pain was the right hand, especially five fingers.

After the right arm amputation, the patient reported that he suffered from PLP. Two years earlier, the patient was referred to the pain clinic for the treatment of her severe PLP. Initially, she was treated with medications such as tramadol (37.5 mg) with acetaminophen (325 mg) and gabapentin 900 mg/day. However, it did not provide meaningful paraesthetic coverage or relief of her hand extremity pain. Finally, we recommended a trial of low-temperature plasma radiofrequency ablation on cervical nerve root (C5–C6/C6–C7/C7–T1).

Coblation of the cervical nerve root was performed. Since there was no standardized technique for applying the low-temperature plasma radiofrequency ablation on cervical nerves, we adopted the method of coblation technique used for the intervertebral disk in treating lumbar discogenic pain. Under strict aseptic conditions, 1% lidocaine was used for local anesthesia. Three Gaotong 17G puncture trocars were placed near the C5–C6, C6–C7, and C7–T1 intervertebral foramen with CT guidance. Then, a coblation needle (DXR-G1100-A185; Xi'an Gaotong Medical Technology Company, LTD, Xi'an, China), attached to low-temperature plasma multifunctional operation system (SM-D380D; Xi'an Gaotong Medical Technology Company, LTD, Xi'an, China), was placed near the C8 nerve root through the puncture trocars. To locate the target nerve, single stimulation (lasting for 5 s, at 1 intensity) in “cut” and “coagulation” model was given to serve as a sensory stimulation test. The stimulation induced radiating pain of the stimulated nerve away from the stimulation site to confirm our target nerve. The needle location was redirected based on the reproduction of the patient's symptoms with minimal intensity. Before proceeding with the lesion, considering that the coblation technique is a nociceptive stimulus and may cause severe pain during operation, sufentanil 10 μg and propofol 100 mg were intravenoused. One minute after injection of the general anesthetic, the coblation operation was performed using the following settings: three of intensity for coblation and six of intensity for coagulation (lasting for 30 s, repeat twice). Coagulation mode is applied to thermally seal the lesions after coblation. Coblation and coagulation were performed in sequence. The needle depth was adjusted to completely make sure coverage and coblation of the target nerve. After coblation, 2 ml of phenol glycerin was injected through the needle. The C6 and C7 nerve root was operated as the same way.

After operation, the patient reported PLP went from 8/10-3-4/10 on the VAS; moreover, pain in three fingers in half including finger 1, finger 2, and finger 3, and 1/2 finger 4 have been released. PLP lasted only for 1–2 s each time and 1–3 times a day and could resolve spontaneously. She was visited at 1-week, 1-month, and 3-month postoperation. In the 1st week, PLP was 3–4/10 on VAS. When necessary, her medications were added but decreased, such as gabapentin to 300 mg/day. After 1 month, she reported a significant improved in sleep, in mood, and in daily activities. Moreover, 3 months later, her pain reached 2–3/10, compared with the baseline VAS (8/10), and his overall pain has decreased. No complications were reported during the follow-up period.


  Discussion Top


PLP refers to the perception of pain in amputated limb or pain following partial or complete deafferentation. PLP is generally difficult to be treated. The treatments include medicine and no medical intervention, while the effects are limited. Therefore, finding a better treatment needs to be focused.

Recently, coblation technology has been demonstrated to have potential for pain management. Coblation is a relatively new technology and has been used in the treatment of NP. It uses radiofrequency energy to excite the electrolytes in a conductive medium such as saline solution, creating energized plasma. This discharge plasma produces chemically active radical species that subsequently interact with organic tissue and possess sufficient energy to break molecular bonds causing tissue dissolution at a low temperature (approximately 40°C–70°C).[19],[20] According to its mechanism, through preventing nociceptive conduction, coblation could suppress dorsal root ganglion activities, thus reducing the erroneous ectopic input to the central nervous system, relieving PLP.

In our PLP case report, the first use of coblation has been successfully reducing pain level, while follow-up visiting is important to evaluate the effects of coblation operations. However, it also needs a number of RCTs further to be designed in PLP coblation. In a word, it supplies a novel navigation in PLP treatments.

Ethics

This study was approved by the local ethical committee.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Acknowledgment

The study was financially supported by National Natural Science Foundation of China (NO.81502553); Project Funded by China Postdoctoral Science Foundation (2017M610947); China Postdoctoral Science Foundation (2017T100091); Beijing Postdoctoral Research Foundation (2017zz-115).

Financial support and sponsorship

Supported by National Natural Science Foundation of China(NO.81502553); Project funded by China Postdoctoral Science Foundation (2017M610947); China Postdoctoral Science Foundation (2017T100091); Beijing Postdoctoral Research Foundation(2017zz-115).

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
Kern U, Busch V, Müller R, Kohl M, Birklein F. Phantom limb pain in daily practice – Still a lot of work to do! Pain Med 2012;13:1611-26.  Back to cited text no. 1
    
2.
Ephraim PL, Wegener ST, MacKenzie EJ, Dillingham TR, Pezzin LE. Phantom pain, residual limb pain, and back pain in amputees: Results of a national survey. Arch Phys Med Rehabil 2005;86:1910-9.  Back to cited text no. 2
[PUBMED]    
3.
Ehde DM, Czerniecki JM, Smith DG, Campbell KM, Edwards WT, Jensen MP, et al. Chronic phantom sensations, phantom pain, residual limb pain, and other regional pain after lower limb amputation. Arch Phys Med Rehabil 2000;81:1039-44.  Back to cited text no. 3
[PUBMED]    
4.
Jensen TS, Krebs B, Nielsen J, Rasmussen P. Phantom limb, phantom pain and stump pain in amputees during the first 6 months following limb amputation. Pain 1983;17:243-56.  Back to cited text no. 4
[PUBMED]    
5.
Jensen TS, Krebs B, Nielsen J, Rasmussen P. Non-painful phantom limb phenomena in amputees: Incidence, clinical characteristics and temporal course. Acta Neurol Scand 1984;70:407-14.  Back to cited text no. 5
[PUBMED]    
6.
Bosmans JC, Geertzen JH, Post WJ, van der Schans CP, Dijkstra PU. Factors associated with phantom limb pain: A 31/2-year prospective study. Clin Rehabil 2010;24:444-53.  Back to cited text no. 6
    
7.
Subedi B, Grossberg GT. Phantom limb pain: Mechanisms and treatment approaches. Pain Res Treat 2011;20:864-8.  Back to cited text no. 7
    
8.
Baron R. Mechanisms of disease: Neuropathic pain – A clinical perspective. Nat Clin Pract Neurol 2006;2:95-106.  Back to cited text no. 8
[PUBMED]    
9.
Fang J, Lian YH, Xie KJ, Cai SN. Pharmacological interventions for phantom limb pain. Chin Med J (Engl) 2013;126:542-9.  Back to cited text no. 9
[PUBMED]    
10.
Sherman RA, Sherman CJ, Parker L. Chronic phantom and stump pain among American veterans: Results of a survey. Pain 1984;18:83-95.  Back to cited text no. 10
[PUBMED]    
11.
Jensen TS, Krebs B, Nielsen J, Rasmussen P. Immediate and long-term phantom limb pain in amputees: Incidence, clinical characteristics and relationship to pre-amputation limb pain. Pain 1985;21:267-78.  Back to cited text no. 11
[PUBMED]    
12.
Jensen TS, Gottrup H, Sindrup SH, Bach FW. The clinical picture of neuropathic pain. Eur J Pharmacol 2001;429:1-1.  Back to cited text no. 12
[PUBMED]    
13.
Bittar RG, Kar-Purkayastha I, Owen SL, Bear RE, Green A, Wang S, et al. Deep brain stimulation for pain relief: A meta-analysis. J Clin Neurosci 2005;12:515-9.  Back to cited text no. 13
[PUBMED]    
14.
Rothgangel AS, Braun SM, Beurskens AJ, Seitz RJ, Wade DT. The clinical aspects of mirror therapy in rehabilitation: A systematic review of the literature. Int J Rehabil Res 2011;34:1-3.  Back to cited text no. 14
[PUBMED]    
15.
Bowering KJ, O'Connell NE, Tabor A, Catley MJ, Leake HB, Moseley GL, et al. The effects of graded motor imagery and its components on chronic pain: A systematic review and meta-analysis. J Pain 2013;14:3-13.  Back to cited text no. 15
    
16.
Appleyard I, Lundeberg T, Robinson N. Should systematic reviews assess the risk of bias from sham-placebo acupuncture control procedures? Eur J Integr Med 2014;6:234-43.  Back to cited text no. 16
    
17.
Trevelyan EG, Turner WA, Robinson N. Acupuncture for the treatment of phantom limb pain in lower limb amputees: Study protocol for a randomized controlled feasibility trial. Trials 2015;16:158.  Back to cited text no. 17
[PUBMED]    
18.
Lee PM, So Y, Park JM, Park CM, Kim HK, Kim JH, et al. Spinal cauda equina stimulation for alternative location of spinal cord stimulation in intractable phantom limb pain syndrome: A case report. Korean J Pain 2016;29:123-8.  Back to cited text no. 18
    
19.
Azzazi A, AlMekawi S, Zein M. Lumbar disc nucleoplasty using coblation technology: Clinical outcome. J Neurointerv Surg 2011;3:288-92.  Back to cited text no. 19
[PUBMED]    
20.
Trial C, Brancati A, Marnet O, Téot L. Coblation technology for surgical wound debridement: Principle, experimental data, and technical data. Int J Low Extrem Wounds 2012;11:286-92.  Back to cited text no. 20
    



This article has been cited by
1 Endoscopic mucosal resection of gastrointestinal polyps with a novel low-temperature plasma radio frequency generator: a non-inferiority multi-center randomized control study
Ming-Yan Cai, Liang Zhu, Xiao-Yue Xu, Jia-Xin Xu, Dan-Feng Zhang, Zhen Zhang, Quan-Lin Li, Wen-Zheng Qin, Li Feng, Jian-Guang Xu, Peng Li, Ping-Hong Zhou
Surgical Endoscopy. 2023;
[Pubmed] | [DOI]
2 Research Progress in the Treatment of Lacrimal Duct Obstruction
?? ?
Advances in Clinical Medicine. 2023; 13(03): 4082
[Pubmed] | [DOI]
3 A clinical study of C arm-guided selective spinal nerve block combined with low-temperature plasma radiofrequency ablation of dorsal root ganglion in the treatment of zoster-related neuralgia
Zhen-Wu Zhang, Yan Zhao, Tian-Yi Du, Juan Zhang, Qiong Wu, Zhe-Yin Wang
Frontiers in Neurology. 2023; 14
[Pubmed] | [DOI]
4 Novel Therapies for the Treatment of Neuropathic Pain: Potential and Pitfalls
Pottathil Shinu, Mohamed A. Morsy, Anroop B. Nair, Abdulaziz K. Al Mouslem, Katharigatta N. Venugopala, Manoj Goyal, Monika Bansal, Shery Jacob, Pran Kishore Deb
Journal of Clinical Medicine. 2022; 11(11): 3002
[Pubmed] | [DOI]
5 Amputation stump management: A narrative review
Yoo Jin Choo, Du Hwan Kim, Min Cheol Chang
World Journal of Clinical Cases. 2022; 10(13): 3981
[Pubmed] | [DOI]
6 Clinical Observation of Low-Temperature Plasma Knife Tonsil Adenoidectomy for Pediatric Snoring and Analysis of Influencing Factors
Li Guo, Yirong Hu, Weiguo Li
Emergency Medicine International. 2022; 2022: 1
[Pubmed] | [DOI]
7 Endoscopic Low-Temperature Plasma Radiofrequency Ablation for Primary Thyroid-Like Low-Grade Nasopharyngeal Papillary Adenocarcinoma
Qing-Yao Zhong,Qiang Sun,Zhao-Hui Liu
Ear, Nose & Throat Journal. 2021; 100(7): 563
[Pubmed] | [DOI]
8 Auricular Therapy for Treating Phantom Limb Pain Accompanied by Jumping Residual Limb: A Short Review and Case Study
Hongfang Tian,Hantong Hu,Xingling Li,Jing Liu,Qin Guo,Yang Li,Dexiong Han
Pain and Therapy. 2021;
[Pubmed] | [DOI]
9 Radiofrequency Techniques for the Alleviation of Post-amputation Phantom Limb Pain: a Systematic Review
James B. Meiling, George M. Raum, Brandon S. Barndt, Nicole V. Nguyen, Christopher T. Ha, Cynthia J. Beeler, F. Clay Smither
Current Physical Medicine and Rehabilitation Reports. 2021;
[Pubmed] | [DOI]
10 Clinical efficacy comparison of low-temperature plasma radiofrequency ablation and Nd:YAG laser in treating recurrent acquired nasolacrimal duct obstruction
Qiyu Qin,Bihua Li,JinJin Ming,Bo Liu,Yujie Mou,Xiuming Jin
Lasers in Medical Science. 2020;
[Pubmed] | [DOI]
11 Masticatory Dysfunction After Computed Tomography–Guided Plasma Ablation vs. Radiofrequency Ablation on Gasserian Ganglion for Idiopathic Trigeminal Neuralgia: A Randomized Controlled Trial
Shuyue Zheng,Xiuhua Li,Liqiang Yang,Liangliang He,Guoqing Cao,Zhanmin Yang,Jiaxiang Ni
Pain Medicine. 2020;
[Pubmed] | [DOI]
12 Comparison of the efficacy of two surgical procedures on adenoidal hypertrophy in children
H. Huang,L. Zhang,Q. Zhang,J. Zhong,L. Fu,Y. Mou
Archives de Pédiatrie. 2019;
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Abstract
Introduction
Case Report
Discussion
References

 Article Access Statistics
    Viewed5292    
    Printed235    
    Emailed0    
    PDF Downloaded490    
    Comments [Add]    
    Cited by others 12    

Recommend this journal